BEST ACCESS SYSTEMS 45HM IDH Max 1300 Especificaciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
1W ELECTRIC SWITCH LOCKS
18
IDH MAX
®
& ELECTROMECHANICAL LOCKS
1W ELECTRIC SWITCH LOCKS
Key & switch positions Remove key Opt. boxes
OC2
7
/
8
"
1
5
/
32
"
Hole cutout
1W7K4
1W7K4
Back view
Side view
Key pos.3 Swt. pos.3 Key pos.1 Swt. pos.1 Key pos 2 Swt. pos.2
Key pos. 1 only
Swt. pos. 1 only
Contact rating ......................................................................110 VAC, 15 amps, resistive
220 VAC, 10 amps, resistive
Horsepower rating .................................................................................. 250 VAC,
1
/
2
HP
Operating temperature ..................................................................up to +221°F (+105°C)
Switch type ..................................................................DPDT (Double pole-double throw)
Switch lock action ..............................................................Momentary (on-center off-on)
Number of switches per assembly ............................................................................One
Key & switch positions Remove key Opt. box
OC2
Contact rating 110 VAC, 15 amps, resistive
220 VAC, 10 amps, resistive
Horsepower rating 125–250 VAC or VDC,
3
/
4
HP; 1, 2, or 3 phase
Operating temperature ........................................................0 to +150°F (-18°C to 66°C)
Switch type ....................................................................TPDT (Triple pole-double throw)
Switch lock action ............................................
Maintained Momentary (on-center off-on)
Number of switches per assembly ............................................................................One
Key pos.1
Swt. pos.1
Key pos.2
Swt. pos.2
Key pos.3
Swt. pos.3
Key pos. 1 only
Swt. pos. 1, 2, and 3*
Limiting plate*
Hole cutout
1
5
/
32
"
7
/
8
"
1W7E2
*Installing the limiting plate limits key removal to switch position 2, or 3. The key is always removed in the vertical position (key position 1). The limiting plate is
available for 1W7E2 only.
Front viewSide view
1W7E2
Vista de pagina 17