OMECHANICAL LOCKS
5
40HM IDH MAX
®
– FUNCTIONS
NXEL–Locked
Fail Safe
• Outside knob/lever
when power is
removed from the
solenoid
• Outside key
• Inside knob/lever.
Applying power to
solenoid; remains locked
while power is on.
Removing power from solenoid Cannot be locked Always unlocked
Removing power from
solenoid
Applying power to solenoid;
remains locked while power is on.
Applying power to
solenoid; remains locked
while power is continuously
applied.
Removing power from
solenoid
Removing power from
solenoid
Applying power to
solenoid; remains locked while
power is continuously applied.
Cannot be locked Always unlocked
LatchFunction
Locked by
Unlocked by
Locked by
Unlocked by
Inside Knob/Lever
Outside Knob/Lever
Operated by
DEL–Locked
Fail Safe
DEU–Unlocked
Fail Secure
NXEU–Unlocked
Fail Secure
Cannot be locked Always unlocked
Cannot be locked Always unlocked
Powered by 12 DC. temperature control module is not needed.
Powered by 12 DC. temperature control module is not needed.
Powered by 12 DC. temperature control module is not needed.
40HM IDH MAX
®
– FUNCTIONS
• Outside knob/lever
when power is
removed from the
solenoid
• Outside key
• Inside knob/lever.
LEL–Locked
Fail Safe
Cannot be locked Always unlocked
• Outside knob/lever
when power is
removed from the
solenoid
• Inside knob/lever.
Applying power to the
solenoid; remains locked
while power is continuously
applied
Removing power from the solenoid
TDEL–Locked
Fail Safe
TDEU–Unlocked
Fail Secure
LEU–Unlocked
Fail Secure
Cannot be locked Always unlocked
Cannot be locked Always unlocked
Powered by 12 DC. temperature control module is not needed.
Powered by 12 DC. temperature control module is not needed.
Powered by 12 DC. temperature control module is not needed.
Powered by 12 DC. temperature control module is not needed.
Outside key
• Outside knob/lever
when power is
removed from the
solenoid.
Latchbolt is dead
-
locked by an
auxiliary latch
Powered by 12 DC. temperature control module is not needed.
Deadbolt extended by:
Inside thumb turn
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts the
deadbolt and latchbolt
simultaneously
• Outside lever when power is
removed
Outside key
• Outside knob/lever
when power is
removed from the
solenoid.
Latchbolt is dead-
locked by an
auxiliary latch
Applying power to the
solenoid; remains locked
while power is continuously
applied
Removing power from the solenoid
Deadbolt operated by:
Outside key
Deadbolt and Latchbolt
retracted simultaneously by:
• Inside knob/lever
• Outside knob/lever when power is
removed
Applying power to the solenoid;
remains locked while power is
continuously applied
Removing power from the
solenoid
Deadbolt operated by:
Outside key
Deadbolt and Latchbolt
retracted simultaneously by:
• Inside knob/lever
• Outside knob/lever when power is
removed
• Outside knob/lever
when power is
removed from the
solenoid
Inside knob/lever.
Latchbolt is dead-
locked by an
auxiliary latch
• Outside knob/lever
when power is
removed from the
solenoid
Inside knob/lever.
Latchbolt is dead-
locked by an
auxiliary latch
• Outside knob/lever
when power is
applied to the
solenoid
• Inside knob/lever.
Cannot be locked Always unlocked
Applying power to the solenoid;
remains locked while power is
continuously applied
Removing power from the
solenoid
Deadbolt extended by:
Inside thumb turn
Deadbolt retracted by:
• Inside thumb turn
• Inside knob/lever retracts the
deadbolt and latchbolt
simultaneously
• Outside knob/lever when power is
removed