Service and Maintenance for Mortise Locks
W Series Service Manual 4–3
Removing
components for
IDH Max Mortise
Locks
Task A. To remove the core:
Note:
Only EEL and EEU function locks have a core.
1. Insert the control key into the core and rotate the key 15 degrees to
the right.
2. Remove the core from the cylinder.
Figure 4.1 Removing the core
Control key
Core
Outside of door