INOX - GENERAL NOTES & COMMENTS
1. Control sample to be provided to Architect for review and approval.
2. Flush doors will be furnished as VT Industries 5502 series or equal with
particleboard core.
3. Interior hollow metal frame will be furnished as 16 gauge, welded, primed for field
painting. All doors and frames to have a sprayed vs. brushed final finish.
4. Contractor to verify transitions and doors to be undercut. Where ventilation is
required doors to be undercut ½”.
5. See A1.0 for additional door, hardware notes and types.
6. Please coordinate with Auburn University Project Manager to determine keying
requirements.
7. Hinges will be furnished in US26D satin chrome plated finish. All other hardware
US32D satin stainless steel finish, except closers which are furnished in aluminum
painted finish to match or where noted to match existing.
AUBURN UNIVERSITY ACCESS CONTROL NOTES & COMMENTS:
*NOTE: This document is for aid in writing specifications for job proposal and is not
intended as a Literal Specification. All proposed Access Control specifications must be
approved by Auburn University Facilities Maintenance & Operations and AU Access
Control Center.
1) All exterior doors shall be electrified and monitored by the LENEL system and software
and meet the requirements of the Access Control Installation Checklist.
2) At least one exterior door shall have a 2010 card reader.
3) MDF and IDF rooms shall have card reader access and shall have substantial space
provided for Access Control and Security systems.
4) MDF and IDF rooms shall only be utilized by Auburn University Department of
Information Technology, Auburn University Access Control, and Auburn University
Department of Public Safety and Security without express written approval of all parties.
5) Electrified exit devices shall be Von Duprin, EL RX 99/98 Series rim device, Electric
Latch Retraction with Request to exit (RQE), with keyed removable center mullions for
double egress doors. All electrified doors shall be installed as Night Latch function, so no
manual locking is required after hours. NO DOUBLE CYLINDER! NO DOGING
DEVICES!
6) All ADA operators shall be LCN 4640 series, mounted on the push side of the door. On
any card access door, the door shall have both a swipe reader and a proximity reader to be
tied into the LENEL system.
7) Door Closers:
Vista de pagina 9