Service and Maintenance for Mortise Locks
4–54 W Series Service Manual
5. Remove the door status switch from the clamp.
Reinstalling the door status switch
1. Install the new door status switch in the clamp so that the door
status switch rests just behind the armored front of the case.
2. Route the door status switch wires or cable as shown in Figure 4.52.
3. Clamp the door status switch wires or cable in the strain relief. Slide
the strain relief into position on the case. It should lock into place.
4. Reinstall the mortise case cover and case spacer. See Task H. To
reinstall the mortise case cover and case spacer: on page 4–48.
5. Replace the mortise case. See Reinstalling components for
IDH Max Mortise Locks on page 4–13 or Reinstalling components
for electrified mortise locks on page 4–32.
Figure 4.52 Replacing the door status switch for mortise locks
(IDH Max shown)
Door status
switch
Armored front
of the case
Door status switch cable
Clamp
Top-right corner
of the case
Strain relief