Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
5
Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
Preparing the door and door jamb
2 Drill holes and mortise for latch face
1 Drill the holes listed below:
■ upper and lower trim holes
—5/8″ diameter
— through door
■ door status switch & LH/LHRB reader wire hole
—7/8″ diameter
— through door
■ field harness & RH/RHRB reader wire hole
—7/8″ diameter
— through door
■ door status switch hole
—1″ diameter
— meets door status switch & LH/LHRB reader wire
hole
■ solenoid wire hole
—3/8″ diameter
— through door
— before drilling chassis hole
■ chassis hole
—2 1/8″ diameter
— through door
— after drilling solenoid wire hole
■ latch hole
—1″ diameter
— meets chassis hole
Note 1: To locate the center of a hole on the opposite
side of the door, drill a pilot hole completely through the
door.
Note 2: For holes through the door, it is best to drill
halfway from each side of the door to prevent the door
from splintering.
2 Mortise the edge of the door to fit the latch face.
Figure 2 Drilling holes and mortising for the latch face
Door status
switch hole
Latch hole
Upper trim
hole
Door status
switch & LH/
LHRB reader
wire hole
Solenoid wire
hole
Chassis hole
Lower trim
hole
Inside of door
Latch face
mortise
Field harness
& RH/RHRB
reader wire
hole
Comentarios a estos manuales