Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Completing the installation at the door
16
18 Install core and throw member
1 Install the blocking plate onto the throw member.
Caution: You must use the blocking plate to
prevent unauthorized access.
2 Insert the control key into the core and rotate the key
15 degrees to the right.
3 Insert the throw member into the core.
4 Insert the core and throw member into the knob/lever
with the control key.
5 Rotate the control key 15 degrees to the left and
withdraw the key.
Note: Be sure to insert the correct throw member into
the core: 6-pin cores require the number “6” throw
member; 7-pin cores require the number “7” throw
member.
Caution: The control key can be used to remove
cores and to access doors. Provide adequate
security for the control key.
19 Install access door
1 Making sure that the access door does not pinch
any wires, insert the tabs of the access door into its
mating slots and swing the door closed.
2 Use a T15 TORX bit driver to secure the access door
with the security screw. Tighten firmly.
Figure 18a Installing the blocking plate and throw
member
Core
Blocking
plate
Throw
member
Figure 18b Installing the core
Core
Control
key
Throw
member
Figure 19 Installing the access door
Security screw
Tabs
Vista de pagina 203